Search results

1 – 3 of 3
Open Access
Article
Publication date: 27 July 2022

Sami Barmada, Alessandro Formisano, Dimitri Thomopulos and Mauro Tucci

This study aims to investigate the possible use of a deep neural network (DNN) as an inverse solver.

Abstract

Purpose

This study aims to investigate the possible use of a deep neural network (DNN) as an inverse solver.

Design/methodology/approach

Different models based on DNNs are designed and proposed for the resolution of inverse electromagnetic problems either as fast solvers for the direct problem or as straightforward inverse problem solvers, with reference to the TEAM 25 benchmark problem for the sake of exemplification.

Findings

Using DNNs as straightforward inverse problem solvers has relevant advantages in terms of promptness but requires a careful treatment of the underlying problem ill-posedness.

Originality/value

This work is one of the first attempts to exploit DNNs for inverse problem resolution in low-frequency electromagnetism. Results on the TEAM 25 test problem show the potential effectiveness of the approach but also highlight the need for a careful choice of the training data set.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering , vol. 41 no. 6
Type: Research Article
ISSN: 0332-1649

Keywords

Open Access
Article
Publication date: 22 April 2024

Sami Barmada, Nunzia Fontana, Leonardo Sandrolini and Mattia Simonazzi

The purpose of this paper is to gain a better understanding on how metasurfaces behave, in terms of currents in each unit cell. A better knowledge of their behavior could lead to…

91

Abstract

Purpose

The purpose of this paper is to gain a better understanding on how metasurfaces behave, in terms of currents in each unit cell. A better knowledge of their behavior could lead to an ad-hoc design for specific applications.

Design/methodology/approach

The methodology used is both theoretical and numerical; it is based on circuit theory and on an optimization procedure.

Findings

The results show that when the knowledge of the current in each unit cell of a metasurface is needed, the most common approximations currently used are often not accurate. Furthermore, a procedure for the termination of a metasurface, with application-driven goals, is given.

Originality/value

This paper investigates the distribution of the currents in a 2D metamaterial realized with magnetically coupled resonant coils. Different models for the analysis of these structures are illustrated, and the effects of the approximations they introduce on the current values are shown and discussed. Furthermore, proper terminations of the resonators on the boundaries have been investigated by implementing a numerical optimization procedure with the purpose of achieving a uniform distribution of the resonator currents. The results show that the behavior of a metasurface (in terms of currents in each single resonator) depends on different properties; as a consequence, their design is not a trivial task and is dependent on the specific applications they are designed for. A design strategy, with lumped impedance termination, is here proposed.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering , vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0332-1649

Keywords

Article
Publication date: 16 November 2021

Sami Barmada, Alessandro Formisano, Jesus C. Hernandez, Francisco José J. Sánchez Sutil and Carlo Petrarca

The lightning phenomenon is one of the main threats in photovoltaic (PV) applications. Suitable protection systems avoid major damages from direct strikes but also nearby strikes…

Abstract

Purpose

The lightning phenomenon is one of the main threats in photovoltaic (PV) applications. Suitable protection systems avoid major damages from direct strikes but also nearby strikes may induce overvoltage transients in the module itself and in the power conditioning circuitry, which can permanently damage the system. The effects on the PV system sensibly depend on the converter topology and on the adopted power switch. In the present study, a comparative analysis of the transient response due to a nearby lightning strike (LS) is carried out for three PV systems, each equipped with a different converter, namely, boost, buck and buck–boost, based on either silicon carbide metal oxide semiconductor field effect transistors (SiC MOSFET) or insulated gate bipolar transistors controlled power switch devices, allowing in this way an analysis at different switching frequencies. The purpose of this paper is to present the results of the numerical analysis to help the design of suited protection systems.

Design/methodology/approach

Using a recently introduced three-dimensional semi-analytical method to simulate the electromagnetic transients caused in PV modules by nearby LSs, we investigate numerically the effect of a LS on the electronic circuits connecting the module to the alternate current (AC) power systems. This study adopts numerical simulations because experimental analyses are not easy to perform and does not grant a sufficient coverage of all statistically relevant aspects. The approach was validated in a previous paper against available experimental data.

Findings

It is found that the load voltage is not severely interested by the strike effects, thanks to the low pass filters present at the converter output, whereas a relatively high overvoltage develops between the negative pin of the inner circuitry and the “ground” voltage reference. The overcurrent present in the active switches is hardly comparable because of the different topologies and working frequencies; however, the highest overcurrent is observed in the buck converter topology, with SiC MOSFET technology, although it shows the fastest decay.

Originality/value

This research proposes, to the best of the authors’ knowledge, a comprehensive comparison of the indirect lighting strike effects on the converter connected to PV panels. A proper design of the lightning and surge protection system should take into account such aspects to reduce the risk of induced overvoltage and overcurrent transients.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering , vol. 41 no. 2
Type: Research Article
ISSN: 0332-1649

Keywords

1 – 3 of 3