Search results

1 – 10 of over 1000
Article
Publication date: 16 April 2024

Jinwei Zhao, Shuolei Feng, Xiaodong Cao and Haopei Zheng

This paper aims to concentrate on recent innovations in flexible wearable sensor technology tailored for monitoring vital signals within the contexts of wearable sensors and…

Abstract

Purpose

This paper aims to concentrate on recent innovations in flexible wearable sensor technology tailored for monitoring vital signals within the contexts of wearable sensors and systems developed specifically for monitoring health and fitness metrics.

Design/methodology/approach

In recent decades, wearable sensors for monitoring vital signals in sports and health have advanced greatly. Vital signals include electrocardiogram, electroencephalogram, electromyography, inertial data, body motions, cardiac rate and bodily fluids like blood and sweating, making them a good choice for sensing devices.

Findings

This report reviewed reputable journal articles on wearable sensors for vital signal monitoring, focusing on multimode and integrated multi-dimensional capabilities like structure, accuracy and nature of the devices, which may offer a more versatile and comprehensive solution.

Originality/value

The paper provides essential information on the present obstacles and challenges in this domain and provide a glimpse into the future directions of wearable sensors for the detection of these crucial signals. Importantly, it is evident that the integration of modern fabricating techniques, stretchable electronic devices, the Internet of Things and the application of artificial intelligence algorithms has significantly improved the capacity to efficiently monitor and leverage these signals for human health monitoring, including disease prediction.

Details

Sensor Review, vol. 44 no. 3
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 20 October 2014

Mohammed Abdullah Al Rashed and Tariq Pervez Sattar

The purpose of this paper is to develop a wireless positioning system. The automation of non-destructive testing (NDT) of large and complex geometry structures such as aircraft…

Abstract

Purpose

The purpose of this paper is to develop a wireless positioning system. The automation of non-destructive testing (NDT) of large and complex geometry structures such as aircraft wings and fuselage is prohibitively expensive, though automation promises to improve on manual ultrasound testing. One inexpensive way to achieve automation is by using a small wall-climbing mobile robot to move a single ultrasound probe over the surface through a scanning trajectory defined by a qualified procedure. However, the problem is to guide the robot though the trajectory and know whether it has followed it accurately to confirm that the qualified procedure has been carried out.

Design/methodology/approach

The approach is to use sophisticated bulk electronics developed for game playing in combination with MATLAB to develop a wireless positioning system.

Findings

The paper describes the development of an inexpensive wireless system comprising an optical spatial positioning system and inertial measurement unit that relates the 3D location of an NDT probe carried by a mobile robot to a computer-aided drawing (CAD) representation of the test structure in a MATLAB environment. The probe is located to an accuracy of ± 2 mm at distances of 5 m.

Research limitations/implications

Positioning range is limited to 5 m. Further development is required to increase this range.

Practical implications

The wireless system is used to develop tools to guide the robot remotely to follow a desired scanning trajectory, obtain feedback about the actual trajectory executed by the robot, know exactly where an ultrasound pulse echo was captured, map identified defects on the CAD and relate them to the real test object.

Originality/value

An inexpensive spatial positioning system with sufficient accuracy for automated NDT purposes.

Details

Industrial Robot: An International Journal, vol. 41 no. 6
Type: Research Article
ISSN: 0143-991X

Keywords

Article
Publication date: 17 September 2018

Ernesto Morales, Stéphanie Gamache, François Routhier, Jacqueline Rousseau and Olivier Doyle

The purpose of this paper is to describe a methodology to measure the circulation area required by a manual or powered wheelchair within a toilet stall and present the range of…

Abstract

Purpose

The purpose of this paper is to describe a methodology to measure the circulation area required by a manual or powered wheelchair within a toilet stall and present the range of possible results that can be collected when used in an experimental bathroom setup.

Design/methodology/approach

A bathroom environment containing a toilet, grab bars and two transparent acrylic panels suspended on rails to simulate walls was built. Three setups were experimented: 1,500 mm from the walls, 1,500 mm diagonally from the toilet and 1,700 mm from the walls. For each of the participants, markers were placed on the back and on the rear of the wheelchair and one on the toes of the participants. The Vicon® optical motion capture system was used to register the markers’ position in the 3D space.

Findings

The methodology proved to be relatively easy to install, efficient and easy to interpret in terms of results. It provides specific points from which it is possible to measure the trajectories of markers and calculate the polygonal projection of the area covered by each participant. The results showed that manual and powered wheelchair users required, respectively, 100 and 300 mm more than the minimum 1,500 mm wall-to-wall area to complete a rotation task in front of the toilet.

Originality/value

These results showed that the 1,500 mm gyration area proposed in the Canadian Code of Construction is not sufficient for manual and powered wheelchair users to circulate easily in toilet stalls. The methodology can provide evidence to support the improvement of construction norms in terms of accessible circulation areas.

Details

Journal of Enabling Technologies, vol. 12 no. 3
Type: Research Article
ISSN: 2398-6263

Keywords

Article
Publication date: 2 May 2023

Hang Guo, Xin Chen, Min Yu, Marcin Uradziński and Liang Cheng

In this study, an indoor sensor information fusion positioning system of the quadrotor unmanned aerial vehicle (UAV) was investigated to solve the problem of unstable indoor…

Abstract

Purpose

In this study, an indoor sensor information fusion positioning system of the quadrotor unmanned aerial vehicle (UAV) was investigated to solve the problem of unstable indoor flight positioning.

Design/methodology/approach

The presented system was built on Light Detection and Ranging (LiDAR), Inertial Measurement Unit (IMU) and LiDAR-Lite devices. Based on this, one can obtain the aircraft's current attitude and the position vector relative to the target and control the attitudes and positions of the UAV to reach the specified target positions. While building a UAV positioning model relative to the target for indoor positioning scenarios under limited Global Navigation Satellite Systems (GNSS), the system detects the environment through the NVIDIA Jetson TX2 (Transmit Data) peripheral sensor, obtains the current attitude and the position vector of the UAV, packs the data in the format and delivers it to the flight controller. Then the flight controller controls the UAV by calculating the posture to reach the specified target position.

Findings

The authors used two systems in the experiment. The first is the proposed UAV, and the other is the Vicon system, our reference system for comparison purposes. Vicon positioning error can be considered lower than 2 mm from low to high-speed experiments. After comparison, experimental results demonstrated that the system could fully meet the requirements (less than 50 mm) in real-time positioning of the indoor quadrotor UAV flight. It verifies the accuracy and robustness of the proposed method compared with that of Vicon and achieves the aim of a stable indoor flight preliminarily.

Originality/value

Vicon positioning error can be considered lower than 2 mm from low to high-speed experiments. After comparison, experimental results demonstrated that the system could fully meet the requirements (less than 50 mm) in real-time positioning of the indoor quadrotor UAV flight. It verifies the accuracy and robustness of the proposed method compared with that of Vicon and achieves the aim of a stable indoor flight preliminarily.

Details

International Journal of Intelligent Unmanned Systems, vol. 12 no. 1
Type: Research Article
ISSN: 2049-6427

Keywords

Article
Publication date: 21 October 2020

Le Fu and Jie Zhao

Admittance control is a typical complaint control methodology. Traditionally, admittance control systems are based on a dynamical relationship described by Voigt model. By…

Abstract

Purpose

Admittance control is a typical complaint control methodology. Traditionally, admittance control systems are based on a dynamical relationship described by Voigt model. By contrast, after changing connection of spring and damper, Maxwell model produces different dynamics and has shown better impact absorption performance. This paper aims to design a novel compliant control method based on Maxwell model and implement it in a robot catching scenario.

Design/methodology/approach

To achieve this goal, this paper proposed a Maxwell model based admittance control scheme. Considering several motion stages involved in one catching attempt, the following approaches are adopted. First, Kalman filter is used to process the position data stream acquired from motion capture system and predict the subsequent object flying trajectory. Then, a linear segments with parabolic blends reaching motion is generated to achieve time-optimal movement under kinematic and joint inherent constraints. After robot reached the desired catching point, the proposed Maxwell model based admittance controller performs such as a cushion to moderate the impact between robot end-effector and flying object.

Findings

This paper has experimentally demonstrated the feasibility and effectiveness of the proposed method. Compared with typical Voigt model based compliant catching, less object bounding away from end-effector happens and the success rate of catching has been improved.

Originality/value

The authors proposed a novel Maxwell model based admittance control method and demonstrated its effectiveness in a robot catching scenario. The author’s approach may inspire other related researchers and has great potential of practical usage in a widespread of robot applications.

Details

Assembly Automation, vol. 41 no. 2
Type: Research Article
ISSN: 0144-5154

Keywords

Article
Publication date: 8 April 2022

Shao-Li Han, Meng-Lin Cai, Hui-Hong Yang, Yun-Chen Yang and Min-Chun Pan

This study aims to leverage inertial sensors via a walk test to associate kinematic variables with functional assessment results among walkable subjects with chronic stroke.

Abstract

Purpose

This study aims to leverage inertial sensors via a walk test to associate kinematic variables with functional assessment results among walkable subjects with chronic stroke.

Design/methodology/approach

Adults with first-ever stroke survivors were recruited for this study. First, functional assessments were obtained by using Fugl–Meyer Assessment for lower extremity and Berg balance scales. A self-assembled inertial measurement system obtained walking variables from a walk test after being deployed on subjects’ affected limbs and lower back. The average walking speeds, average range of motion in the affected limbs and a new gait symmetry index were computed and correlated with the two functional assessment scales using Spearman’s rank correlation test.

Findings

The average walking speeds were moderately correlated with both Fugl–Meyer assessment scales (γ = 0.62, p < 0.01, n = 23) and Berg balance scales (γ = 0.68, p < 0.01, n = 23). After being modified by the subjects’ height, the new gait symmetry index revealed moderate negative correlations with the Fugl–Meyer assessment scales (γ = −0.51, p < 0.05) and Berg balance scales (γ = −0.52, p < 0.05). The other kinematics failed to correlate well with the functional scales.

Practical implications

Neuromotor and functional assessment results from inertial sensors can facilitate their application in telemonitoring and telerehabilitation.

Originality/value

The average walking speeds and modified gait symmetry index are valuable parameters for inertial sensors in clinical research to deduce neuromotor and functional assessment results. In addition, the lower back is the optimal location for the inertial sensors.

Details

Sensor Review, vol. 42 no. 3
Type: Research Article
ISSN: 0260-2288

Keywords

Open Access
Article
Publication date: 17 January 2023

Xing Ying

The purpose of this paper investigates dynamic ease distributions of clothes at bust and waist lines with different body surface angle by using a Qualisys three-dimensional motion

Abstract

Purpose

The purpose of this paper investigates dynamic ease distributions of clothes at bust and waist lines with different body surface angle by using a Qualisys three-dimensional motion capture system (3DMCS).

Design/methodology/approach

The current method first obtain the specific markers of participants and their clothes along the bust and waist lines through 3DMCS, then using the least square method and four piecewise polynomial fitting participants and their clothes' bust and waist curves. The coordinates of the markers were tracked by the 3DMCS, while the participants under different body surface angle walked on a treadmill calculated the distances of markers coordinates to the participants' bust and waist curves. Finally, the data of samples were analyzed. It was found that the dynamic ease distributions showed different patterns at different body surface angle.

Findings

The results revealed the bust convex angle is 26.53 degrees (Specification:X3) and back slope angle is 13.96 degrees (Specification: Y1), the fluctuation of participant ease distributions on bust section was most obvious, and the maximum fluctuation value was ±20 mm and ±25 mm. The ease distributions of participant waist section fluctuated most obviously when the bust convex angle is 28.10 degrees (Specification: X5) and the back slope angle is 13.96 degrees (Specification: Y1), and the maximum fluctuation was ±30 mm and ±20 mm. The bust convex angle has the greatest influence on 1# garment, and the back slope angle has the greatest influence on 2# garment.

Originality/value

Currently, there is little information in the literature about dynamic ease distributions of garment on a different body types. This paper takes different body surface angles as the research objects to analyze the ease distributions of different clothes, the conclusion can provide reference data for 3D garment modeling and improve the authenticity of virtual garment fitting.

Details

International Journal of Clothing Science and Technology, vol. 35 no. 2
Type: Research Article
ISSN: 0955-6222

Keywords

Article
Publication date: 27 April 2020

Seungjun Woo, Francisco Yumbla, Chanyong Park, Hyouk Ryeol Choi and Hyungpil Moon

The purpose of this study is to propose a novel plane-based mapping method for legged-robot navigation in a stairway environment.

Abstract

Purpose

The purpose of this study is to propose a novel plane-based mapping method for legged-robot navigation in a stairway environment.

Design/methodology/approach

The approach implemented in this study estimates a plane for each step of a stairway using a weighted average of sensor measurements and predictions. It segments planes from point cloud data via random sample consensus (RANSAC). The prediction uses the regular structure of a stairway. When estimating a plane, the algorithm considers the errors introduced by the distance sensor and RANSAC, in addition to stairstep irregularities, by using covariance matrices. The plane coefficients are managed separately with the data structure suggested in this study. In addition, this data structure allows the algorithm to store the information of each stairstep as a single entity.

Findings

In the case of a stairway environment, the accuracy delivered by the proposed algorithm was higher than those delivered by traditional mapping methods. The hardware experiment verified the accuracy and applicability of the algorithm.

Originality/value

The proposed algorithm provides accurate stairway-environment mapping and detailed specifications of each stairstep. Using this information, a legged robot can navigate and plan its motion in a stairway environment more efficiently.

Details

Industrial Robot: the international journal of robotics research and application, vol. 47 no. 4
Type: Research Article
ISSN: 0143-991X

Keywords

Article
Publication date: 17 June 2021

Zeguo Yang, Mantian Li, Fusheng Zha, Xin Wang, Pengfei Wang and Wei Guo

This paper aims to introduce an imitation learning framework for a wheeled mobile manipulator based on dynamical movement primitives (DMPs). A novel mobile manipulator with the…

Abstract

Purpose

This paper aims to introduce an imitation learning framework for a wheeled mobile manipulator based on dynamical movement primitives (DMPs). A novel mobile manipulator with the capability to learn from demonstration is introduced. Then, this study explains the whole process for a wheeled mobile manipulator to learn a demonstrated task and generalize to new situations. Two visual tracking controllers are designed for recording human demonstrations and monitoring robot operations. The study clarifies how human demonstrations can be learned and generalized to new situations by a wheel mobile manipulator.

Design/methodology/approach

The kinematic model of a mobile manipulator is analyzed. An RGB-D camera is applied to record the demonstration trajectories and observe robot operations. To avoid human demonstration behaviors going out of sight of the camera, a visual tracking controller is designed based on the kinematic model of the mobile manipulator. The demonstration trajectories are then represented by DMPs and learned by the mobile manipulator with corresponding models. Another tracking controller is designed based on the kinematic model of the mobile manipulator to monitor and modify the robot operations.

Findings

To verify the effectiveness of the imitation learning framework, several daily tasks are demonstrated and learned by the mobile manipulator. The results indicate that the presented approach shows good performance for a wheeled mobile manipulator to learn tasks through human demonstrations. The only thing a robot-user needs to do is to provide demonstrations, which highly facilitates the application of mobile manipulators.

Originality/value

The research fulfills the need for a wheeled mobile manipulator to learn tasks via demonstrations instead of manual planning. Similar approaches can be applied to mobile manipulators with different architecture.

Details

Industrial Robot: the international journal of robotics research and application, vol. 48 no. 4
Type: Research Article
ISSN: 0143-991X

Keywords

Article
Publication date: 19 June 2017

Zhelong Wang and Ye Chen

In sensor-based activity recognition, most of the previous studies focused on single activities such as body posture, ambulation and simple daily activities. Few works have been…

Abstract

Purpose

In sensor-based activity recognition, most of the previous studies focused on single activities such as body posture, ambulation and simple daily activities. Few works have been done to analyze complex concurrent activities. The purpose of this paper is to use a statistical modeling approach to classify them.

Design/methodology/approach

In this study, the recognition problem of concurrent activities is explored with the framework of parallel hidden Markov model (PHMM), where two basic HMMs are used to model the upper limb movements and lower limb states, respectively. Statistical time-domain and frequency-domain features are extracted, and then processed by the principal component analysis method for classification. To recognize specific concurrent activities, PHMM merges the information (by combining probabilities) from both channels to make the final decision.

Findings

Four studies are investigated to validate the effectiveness of the proposed method. The results show that PHMM can classify 12 daily concurrent activities with an average recognition rate of 93.2 per cent, which is superior to regular HMM and several single-frame classification approaches.

Originality/value

A statistical modeling approach based on PHMM is investigated, and it proved to be effective in concurrent activity recognition. This might provide more accurate feedback on people’s behaviors.

Practical implications

The research may be significant in the field of pervasive healthcare, supporting a variety of practical applications such as elderly care, ambient assisted living and remote monitoring.

1 – 10 of over 1000